  J1 water humidifier Air Humidifier

  At this stage, many edible mushroom factories choose to install edible mushroom humidifiers to adjust the humidity of indoor air. However, some customers and the editor reported that the good equipment suddenly disappeared from the fog. What is going on? How to solve it? Next, we will introduce to you the most common causes and solutions of this failure.

  1. The mushroom humidifier is not cleaned on time

  Solution: No matter what equipment it is, you need to remember to clean it on time. Usually, the equipment needs to be thoroughly cleaned after running for a certain period of time. It should be noted that the water in the equipment should be filtered water as much as possible, so as to prevent the nebulizer from forming. Scale out, if non-filtered water is used, the calcium and magnesium ions in the water usually cause secondary pollution to the indoor air during the humidification process.

  2. The fan inside the device is stuck or malfunctioning

  Solution: When the edible mushroom humidifier is running, it mainly uses the high-frequency vibration of the stainless steel atomizer to generate water mist, and uses a special fan to transmit the water mist to the place that needs to be humidified. If the device runs normally but does not fog up during operation, the fault may lie in its fan. At this time, you can properly add some lubricating oil to the fan, and then gently tap it twice to run normally.

  3. Scale is formed on the atomizer

  Solution: The scale on the atomizer will also cause the edible fungus humidifier to not work well. If the equipment is windy and fog-free, it is likely to be caused by the scale formed by not cleaning the atomizer for a long time. . This condition requires the application of a weak acid solution to clean the nebulizer. Note that strong acid solutions cannot be used to prevent corrosion of the atomizer.