Several reasons and solutions for ultrasonic humidifiers not fogging!

source:Optimization dedicated    release time:2022-09-07    Hits:     Popular:aromatherapy diffuser direct sales

  

  1. The water level of the ultrasonic humidifier in the water tank is not suitable, resulting in no fog

  The reason why the ultrasonic industrial humidifier does not fog: There is a main atomizer plate in the center of the humidifier, called the atomizer plate. The nebulizer plate is placed in the tank. If the water level is not at the proper height, no fog will be created.

  Solution for inappropriate water level: The ultrasonic atomizer plate core is soaked in water and atomized by the principle of ultrasonic vibration, and the principle of ultrasonic vibration has very strict requirements on the water level! The water level of the atomizing plate is generally not standard at a height of 7 cm. Adjust the height to strengthen the atomizing plate. Industrial humidifiers also need to sit smoothly!

  2. The drying of the water in the humidifier box is also a common cause of fogging of the ultrasonic humidifier

  The reason why the ultrasonic industrial humidifier does not fog: the humidifier also consumes water when it works, because the fog is caused by water.

  Solution for drying tank water: Conventional humidification is a common method, manual operation is more troublesome, and drying of tank water will cause damage to the atomizing plate, so when purchasing an ultrasonic humidifier, you need to pay attention to purchasing those with conventional automatic water addition. Functional humidifier.

  3. Water quality problems caused by the mist of ultrasonic humidifiers

  The reason why the humidifier in the ultrasonic industry does not have problems: the water quality problem mainly occurs when the atomizing plate is blocked, the scale is larger than the atomized particles, there are many scales with poor water quality, and the atomizing plate is blocked by scale is one of the main reasons.

  Solution to water quality problems: Add cleaning solution to dissolve scale, such as detergent, cola, soda water, etc.

  However, the nebulizer is a consumable item, which must be damaged to a certain extent and needs to be replaced regularly, so humidifier users need to prepare some nebulizers.