Precautions for installation of industrial humidification equipment.humidifier diffuser Manufacturing

source:Optimization dedicated    release time:2023-03-25    Hits:     Popular:aromatherapy diffuser direct sales

  J16 Air Humidifier

  The equipment shall be installed horizontally. The external PVC pipe fittings shall be sealed to prevent air and water leakage. When the external water supply pressure is insufficient, it is necessary to connect the booster pump to make its water supply pressure greater than

  1kg /cm 3 。 The connection between the water inlet interface of the equipment and the water supply pipeline must be connected by the hose with lock nut on both sides. Because there is a seal ring in the lock nut of the connecting hose,

  There is no need to wrap silk hemp at the connecting thread mouth to prevent water leakage. When connecting multiple equipment on a water supply pipeline, the water supply branch line of each equipment must be connected with a water supply cutoff to

  It is convenient for future maintenance. For the newly installed water supply pipeline, a certain amount of water should be drained first for the cleaning of the newly installed pipeline to prevent impurities from plugging in the new pipeline

  After the equipment is installed stably, the mist outlet pipeline of the equipment can be sealed and connected according to the pre-designed pipeline direction. During connection, attention should be paid to: set up flange connection at the point near the equipment

  Disc, or connected with hose, which is convenient for future equipment maintenance; In pipeline connection, the distance from the near end of the equipment is relatively low, and the distance from the far end of the equipment is relatively low

  At a higher level, the lowest point of all mist outlets of the pipeline shall be higher than 1/3 of the pipeline diameter, so as to ensure that the accumulated water in the transmission pipeline is completely returned to the equipment and the pipeline is smooth

  Open; In order to make the humidification distribution in the humidification space uniform, the pipeline can be connected with several fog outlets according to the actual situation, and the diameter of the fog outlet can be selected according to the actual situation. Pipeline connection

  "U" shaped direction is not allowed in the connection, because this connection will cause condensation and water blocking of the pipeline, affecting the normal operation of the equipment