I. Separation:
Separation is cement and ultra-high pressure humidifier separation, that is, from the surface looks quite much water, after a while the above is a layer of water, the following is a layer of cement, no bubble. The main reason for the separation is no bubble. May look up the observation mouth foam is normal, if the normal, the function switch to the stop position, and ultrahigh pressure humidification on both valve closed, the air bag can gauge pressure to 15 kq, the safety valve will automatically exhaust is normal after 15 KP, (sometimes lower normal, high separation, majority is pump or pump pressure caused by the short). If the foaming of the mouth is normal, it may be caused by the high pressure water pump not conveying the ultra-high pressure humidifier or the high pressure air pump not pumping. In addition, if the steel wire ball in the ultra-high pressure humidifier is filled with cement, there will be no bubble.
To sum up, the ultra-high pressure humidifier looks more complex, and it is relatively simple to separate each part into a part of the view (air pump, water pump, ultra-high pressure humidifier).
Two, air pump inlet mud:
The main reason why cement slurry enters the air pump is that the manual check valve is not closed in time after shutting down. It must be noted that after the shutdown, because there is a certain pressure in the pipeline memory, it can cause the foam cement to backflow to the ultra-high pressure humidifier and air bag and high pressure air pump, so the manual check valve must be closed after the shutdown.
Three, hydraulic part:
Motor weakness: the main reason for motor weakness is the low pressure of the pressure gauge on the left. The adjustable manual relief valve is less than 10Mpa. If the adjustable hand relief valve does not boost the pressure, the manual relief valve may be blocked.
Four, cement slurry transportation part
1. Box back pulp: it is caused by wear and tear of the leather bowl. It must be replaced with a new leather bowl.
2. The conveying cylinder is not reversed after the head: it is caused by the induction switch or the relay is seriously ablated, which must be replaced. Pay attention to the relay model and the switch model (the induction switch is composed of a normally open and a normally closed).
Five, ultra high pressure humidifier is not foaming:
If the steel wire ball in the ultra-high pressure humidifier manufacturer enters the cement and rust is serious, it may cause the foaming quality to decrease, even not foaming.
Read recommendations:
buying air purifier products, you need to understand several hard power indicators of the product
Ultrasonic humidifier humidification should pay attention to where?
NextHow to balance the humidity of ultrasonic humidifier
Popular recommendation
K3 Home air purifier
2021-09-14A24 aroma diffuser ultrasonic diffuser
2021-09-15H03 Heater Fan
2021-09-14K5 Air Purifier
2021-09-14F10 neck fan Cooling Fan
2021-09-14Use an air purifier to prevent danger!air purifier covid wholesale
2021-10-20How to improve the air in the car?Air purifier Vendor
2022-06-15How to use the car air purifier?
2022-05-27The principle of air purifier purifying smog.Air purifier
2021-12-14How often does the filter element of the air purifier change?
2021-10-13Does the humidifier emit radiation
2024-09-28Is using a humidifier at home harmful to the body?
2024-09-09How long does a dehumidifier usually run per day?
2024-09-09Humidifier classification
2024-08-24Humidifiers nourish daily life
2024-08-17Common classification methods for humidifiers
2024-08-10How to dehumidify with a dehumidifier
2024-07-22Working process of dehumidifier
2024-07-22High pressure micro fog humidifier for air conditioning unit
2024-07-13What are the possible reasons why humidifiers do not produce fog
2024-07-08Contact the following for inquiries regarding our services and products.