CREATIVITY CHANGES YOUR LIFE

Tel: +86 0755-84870739

Email: info@nexhc.com

Home  >  News  >  Optimization dedicated

News

Company news | Industry news | Exhibitions and events | Optimization dedicated | aromatherapy diffuser |

Air purifier failure repair method.Home air purifier manufacturer

source:Optimization dedicated    release time:2021-12-13    Hits:     Popular:aromatherapy diffuser direct sales

  K4 Air Purifier

  Many people often encounter many failures in the process of using air purifiers. At this time, they need to be repaired. Today, the editor of Songchun Electric will introduce some common failures and repair methods of air purifiers!

  1. The power indicator does not light up and the fan does not rotate. First check the power transformer and fuse. Use a universal meter to measure the resistance to see if the coil or fuse is burned out. If it is short-circuited, replace the same type of transformer or fuse in time.

  2. Fire between the two poles of the negative ion generator. The positive and negative plates are bent and deformed and rubbed, or the air humidity in the use environment is too high, which will easily cause the negative ion generator to ignite. You can use pliers to check and correct the pole piece. If there is no response, you can move the air purifier to a place with dry air for a short time, so that it can usually be solved.

  3. The power indicator is on, but the fan does not rotate. The power indicator light is on to indicate that the high-voltage circuit is normally energized, and it may be that the fan is malfunctioning. First check whether the bearings are severely worn and whether there are foreign objects in the middle of the fan blades. If there is no problem, use a multimeter to measure whether there is a circuit break in the motor circuit. If there is a circuit break in the motor unit, replace the fan motor of the same specification.

  4. The output concentration of negative ions is low, and the purification effect is reduced. There are many factors for the low concentration of negative ion output of the air purifier. It may be excessive dust and dirt on the electrode and filter, bending and deformation of the positive and negative plates, or the high voltage is too low. First, clean up the dirt on the electrode and the filter, check and correct the positive and negative plates, if there is no effect, then check the high-voltage circuit. Use a multimeter to check the rectifier tube, step-up transformer, capacitor, etc.


Read recommendations:

K6 portable air purifier Car Air purifier

H04 Heater Fan

Hotel Fragrance Matters!

electric aroma diffuser

usb humidifier Processor

Latest news

Hot

Inquiries

Contact the following for inquiries regarding our services and products.

Inquiry form