The constant temperature and humidity machine operates through three interrelated systems: refrigerant circulation system, air circulation system, and electrical automatic control system. It is suitable for providing a suitable environment for industries such as electronics, communication, hardware, and chemical engineering.
The difference between the accuracy and uniformity of constant temperature and humidity machines: Many users are unaware of the difference between the two. For example, the requirement is 20 degrees ± 2 degrees, and the humidity is ± 5% relative humidity. In fact, there is a significant difference between the two; In fact, the term precision is incorrect. Accuracy should refer to the display accuracy and control accuracy of the instrument. In general, the instrument display accuracy temperature is 0.1 ℃, humidity is 0.1% RH, control accuracy temperature is 0.3 ℃, and humidity is about 1% RH.
The correct expression for a constant temperature and humidity machine should be volatility, which refers to the difference between the actual measured value and the set value of the instrument. This can affect the sensitivity of the sensor, the accuracy of the control instrument, and the response speed of the executing components. The more obvious the value, the more stable the temperature and humidity at the same point. According to its own understanding, it is often referred to as' accuracy '. Uniformity refers to the difference from the average value of the entire control area. The higher the value, the worse the uniformity in space. The accuracy index of a constant temperature and humidity machine is easy to achieve, while the uniformity index is difficult to achieve. It not only has high requirements for instrument sensors, but also has high requirements for the air duct design and control system of the entire system. Generally speaking, positive or negative 2 degrees should refer to accuracy (volatility). If it is a laboratory with high precision requirements, then it is consistent and therefore needs to maintain clarity in communication.
Read recommendations:
The working principle of dynamic air purifier works in the food workshop.air humidifier price
portable air purifier..Comparison of advantages and disadvantages of several humidifiers
Nextportable air purifier.Cleaning methods for constant temperature and humidity machines
Popular recommendation
J9 usb humidifier
2021-09-14K3 Home air purifier
2021-09-14J16 Air Humidifier
2021-09-14F16 desk fan Cooling Fan
2021-09-14A19 Aroma Diffuser
2021-09-14The importance of negative ions to the human body.air purifier covid Processor
2021-11-18Where is the best place to install the car air purifier?portable air purifier Vendor
2021-12-01Activated carbon filter
2022-04-07Negative ion air conditioner purifies the air?
2022-06-11The choice and use of air purifiers?Car Air purifier
2022-01-18Does the humidifier emit radiation
2024-09-28Is using a humidifier at home harmful to the body?
2024-09-09How long does a dehumidifier usually run per day?
2024-09-09Humidifier classification
2024-08-24Humidifiers nourish daily life
2024-08-17Common classification methods for humidifiers
2024-08-10How to dehumidify with a dehumidifier
2024-07-22Working process of dehumidifier
2024-07-22High pressure micro fog humidifier for air conditioning unit
2024-07-13What are the possible reasons why humidifiers do not produce fog
2024-07-08Contact the following for inquiries regarding our services and products.