CREATIVITY CHANGES YOUR LIFE
Tel: +86 0755-84870739
Email: info@nexhc.com
Company news | Industry news | Exhibitions and events | Optimization dedicated | aromatherapy diffuser |
source:Optimization dedicated release time:2022-09-07 Hits: Popular:aromatherapy diffuser direct sales
The ultrasonic industrial humidifier atomizes the water into ultra-fine particles of 1-5 microns through ultrasonic high-frequency vibration, and then sprays it through the air moving device to evenly diffuse into the air, so as to achieve the humidification effect. Because ultrasonic industrial humidifiers have many advantages such as easy operation, small size, small atomized particles, and high humidification efficiency, they are widely used, such as textile industry, aquaculture, artificial landscape, etc.
1. Too much water in the tank
There is always a misunderstanding: the more water in the water tank of the ultrasonic humidifier, the greater the amount of fog. In fact, the water level in the water tank is too high, which will cause the water mist to gather and collide seriously, which will quickly condense into water droplets, and the amount of mist will naturally be greatly reduced. Under normal circumstances, the water level can be diffused over the induction probe on the atomizing plate.
2. Too much scale on the atomizing plate
If the humidifier is used for a long time, the atomizing plate will accumulate scale, and after the backlog reaches a certain level, the atomizing sheet will be blocked, which will affect the mist output of the machine. Therefore, in the process of use, it is necessary to regularly clean or replace the atomizing plate and atomizing sheet. Under normal circumstances, clean the water tank once every two weeks to keep the water tank clean. At the same time, if the water quality is poor, a new water source needs to be replaced.
3. The circuit board fuse is damaged
After long-term use of the ultrasonic humidifier, the fuse will be damaged or even damaged, which will also cause a small amount of fog. In this case, replacing the fuse with a new one can solve it.
4. The atomizing sheet is broken or worn
The atomizing sheet is a lossy part and has a certain service life. In the working state of high frequency vibration, the atomizing sheet will burn out, resulting in no fog phenomenon. In this case, a new atomizing plate or atomizing sheet should be replaced.
5. There are too many elbows in the fog pipe or the pipe is too long
The vertical multi-curve layout is easy to cause water vapor ventilation blockage, which is not easy to discharge, thus affecting the humidification efficiency. Ultrasonic humidifier pipeline installation is recommended to be installed on a flat surface with fewer curves.
Read recommendations:
The functions and advantages of aroma diffusers.aroma diffuser
Industrial dehumidifier purchase
NextWorkshop Humidity Control Printing Spray Humidifier Solutions
Popular recommendation
F05 Cooling Fan
2021-09-14F13 Cooling Fan
2021-09-14A1 aroma diffuser.aromatherapy diffuser
2021-09-14A17 Aroma Diffuser
2021-09-14TS06
2022-02-17Should the humidifier be placed at the head of the bed or at the end of the bed?
2022-04-01Why do you think you don't need an air purifier?air purifier covid company
2022-07-07How to use the smart aroma diffuser for home use better?
2022-03-16What technology does a good air purifier need? (2)Air purifier Production
2021-10-16Air purifier red light instrument knowledge
2022-01-07Does the humidifier emit radiation
2024-09-28Is using a humidifier at home harmful to the body?
2024-09-09How long does a dehumidifier usually run per day?
2024-09-09Humidifier classification
2024-08-24Humidifiers nourish daily life
2024-08-17Common classification methods for humidifiers
2024-08-10How to dehumidify with a dehumidifier
2024-07-22Working process of dehumidifier
2024-07-22High pressure micro fog humidifier for air conditioning unit
2024-07-13What are the possible reasons why humidifiers do not produce fog
2024-07-08Contact the following for inquiries regarding our services and products.