CREATIVITY CHANGES YOUR LIFE

Tel: +86 0755-84870739

Email: info@nexhc.com

Home  >  News  >  Optimization dedicated

News

Company news | Industry news | Exhibitions and events | Optimization dedicated | aromatherapy diffuser |

Precautions in installation of humidifier equipment.humidifier diffuser manufacture

source:Optimization dedicated    release time:2022-11-21    Hits:     Popular:aromatherapy diffuser direct sales

  J31 Air Humidifier

  The equipment shall be installed horizontally. External PVC pipe fittings shall be sealed to prevent air and water leakage. When the external water supply pressure is insufficient, the booster pump shall be connected to make its water supply pressure greater than 1kg/cm 3. The connection between the water inlet interface of the wet film humidifier equipment in the machine room and the water supply pipeline must be made with a hose with locknuts on both sides. Because there is a sealing ring in the locknut of the connecting hose, the connecting screw mouth does not need to be wound with silk hemp to prevent water leakage. When connecting multiple equipment on one water supply pipeline, the water supply branch line of each equipment must be connected to a water supply shut-off gate to facilitate future maintenance. A certain amount of water shall be discharged from the newly installed water supply pipeline for cleaning the newly installed pipeline to prevent impurities in the new pipeline from blocking the water inlet solenoid valve and causing water feeding failure.

  Humidifier installation

  After the equipment is installed stably, the mist outlet pipeline of the equipment can be sealed and connected according to the pre designed pipeline route. When connecting, attention should be paid to: set up a flange connection plate near the equipment point, or connect it with a hose, which is ready for future equipment maintenance; In the pipeline connection, the distance from the near end of the equipment is relatively low, and the distance from the far end of the equipment is relatively high. The low points of all the fog outlets of the pipeline should be higher than 1/3 of the pipeline diameter, so as to ensure that all the accumulated water in the transmission pipeline returns to the equipment and the pipeline is smooth; In order to make the humidification distribution in the humidification space even, the pipeline can be connected with several fog outlets according to the actual situation, and the diameter of the fog outlet can be selected according to the actual situation. The "U" trend is prohibited in the pipeline connection, because such connection will cause condensation and water blockage of the pipeline and affect the normal operation of the equipment.


Read recommendations:

J17 Air Humidifier

TS01

Precautions for the use of negative ion humidifier.Humidifier Processing

air humidifier direct sales

portable air purifier

Latest news

Hot

Inquiries

Contact the following for inquiries regarding our services and products.

Inquiry form