CREATIVITY CHANGES YOUR LIFE
Tel: +86 0755-84870739
Email: info@nexhc.com
Company news | Industry news | Exhibitions and events | Optimization dedicated | aromatherapy diffuser |
source:Optimization dedicated release time:2022-09-07 Hits: Popular:aromatherapy diffuser direct sales
Modern people pay more and more attention to the impact of the environment on the human body, and the relative humidity of the air in the working environment is not up to standard, which will accelerate the demise of life or the deterioration of commodities. Everyone is in dry air, the environmental humidity is too low, and working for a long time in the natural environment is prone to skin lacerations, which is not conducive to physical and mental health. Especially in large industrial workshops, the temperature is high and the environmental humidity is low, which is harmful to production and manufacturing, and has certain harm to the workers' body and psychology. At this time, humidification can be performed according to the installed industrial humidifier, generally because of the problem of poor environmental humidity. can be solved.
In each region, the laws of air humidity in the natural environment are different. Taking the production workshop of electronic components as an example, the electronic workshop has high regulation of gas air humidity and dust, mainly because the sterile environment of the production workshop is low in humidity, coupled with friction The electrostatic induction caused by the electronic components, the dust is adsorbed on the electronic components, which has caused great harm to the product quality and has an adverse impact on the healthy development of the company. Therefore, the electronic components production workshop is more humidified by the equipment industry. The humidification of the production workshop of the electronic components can also be used to absorb dust through the water mist to achieve the effect of ash removal and ensure the normal operation of the electronic components production workshop.
Suitable for electronic equipment manufacturing workshops, it can not only provide humidity, eliminate static electricity, but also absorb floating dust. However, it should not cause harm to electronic products in the production workshop. Therefore, it is very important to choose the right air humidifier. At present, there are many types of industrial humidifiers on the market. Among them, the ultrasonic air humidifier is more commonly used. It mainly uses the high-frequency vibration of the ultrasonic atomizing sheet to spray the water mist in the river water, so as to achieve the real humidification effect. Solve the problem of poor environmental humidity.
According to their main use, air humidifiers are divided into household humidifiers and industrial humidifiers. In industrial humidifiers, ultrasonic air humidifiers use high-frequency fluctuations of ultrasonic waves. Ultrasonic air humidifiers have high compressive strength, uniform humidification, high humidification efficiency, environmental protection and energy saving, power saving, long service life, and positive humidity balance. Water, active maintenance, thermal evaporative air humidifiers are also known as electrically heated air humidifiers. Its principle is to heat the water in the heated body to 100 degrees to generate water vapor, which is sent out by a centrifugal fan. Therefore, the electric heated air humidifier is a very simple professional and technical humidification method. The disadvantage is that it consumes a lot of electricity, cannot be burned in empty, poor safety performance, and simple electric heater scale.
Secondly, for the common problems of industrial humidifiers, the application should be placed at room temperature for 30 minutes before starting to use;
1. Do not contact drinking water with dirt, dirt, oil stains, acid and alkali, etc., use an air humidifier to humidify. Continuously clean the sensor surface to keep the environment clean;
2. It is necessary to centrally clean the atomization control module and the inner cavity of the housing in the storage tank of the air humidifier, generally once every 2-3 months;
3. When not in use for a long time, the unnecessary water in the water storage tank should be discharged to avoid long-term leakage and foam as the atomization control module, which will accelerate the embrittlement rate and endanger the life of the air humidifier.
4. After the equipment has been used for a long time, if the above treatment still cannot solve the problem, please remove and replace the energy sheet or make an atomization control module;
Read recommendations:
Is the air disinfection machine harmful to children? Which problems are normal?
How to improve the ambient humidity in the packaging plant?
NextHow should industrial humidifiers use water?
Popular recommendation
F05 Cooling Fan
2021-09-14F16 desk fan Cooling Fan
2021-09-14F19 Cooling Fan
2021-09-14J16 Air Humidifier
2021-09-14K5 Air Purifier
2021-09-14How to choose the right fragrance oil
2022-05-11Which air purifier to choose?air purifier covid manufacturer
2021-10-14There are so many differences between an aroma diffuser and a humidifier
2022-02-25What are the benefits and harms of aromatherapy machines.essential oil diffuser
2022-06-09How to use the aromatherapy machine?
2022-03-24Does the humidifier emit radiation
2024-09-28Is using a humidifier at home harmful to the body?
2024-09-09How long does a dehumidifier usually run per day?
2024-09-09Humidifier classification
2024-08-24Humidifiers nourish daily life
2024-08-17Common classification methods for humidifiers
2024-08-10How to dehumidify with a dehumidifier
2024-07-22Working process of dehumidifier
2024-07-22High pressure micro fog humidifier for air conditioning unit
2024-07-13What are the possible reasons why humidifiers do not produce fog
2024-07-08Contact the following for inquiries regarding our services and products.