CREATIVITY CHANGES YOUR LIFE

Tel: +86 0755-84870739

Email: info@nexhc.com

Home  >  News  >  Optimization dedicated

News

Company news | Industry news | Exhibitions and events | Optimization dedicated | aromatherapy diffuser |

Installation and maintenance of ultrasonic industrial humidifiers.humidifier diffuser price

source:Optimization dedicated    release time:2023-06-06    Hits:     Popular:aromatherapy diffuser direct sales

  


  The installation location of the equipment can be selected based on the following factors:

  ① The maximum relative humidity of the required humidification environment. When the maximum relative humidity is above 75% RH in the required humidification environment, the humidification equipment should be installed outside the required humidification environment; When the maximum relative humidity is below 75% RH, the humidification equipment can be installed in a humidification environment.

  ② The required humidification environment has explosion-proof requirements; All explosion-proof requirements for the required humidification field, and the installation of humidification equipment should be in non explosion-proof areas outside the required humidification environment.

  ③ If the temperature in the required humidification environment is below zero degrees Celsius, the equipment must be installed in a location outside the required humidification environment where the temperature is above zero degrees Celsius.

  ④ If there is a large amount of floating dust in the required humidification environment, which may cause poor air intake and operation of the equipment, it should be considered to install the equipment outside the required humidification environment.

  After determining the installation position of the equipment based on the above conditions, the installation height of the equipment should also be considered. Generally, the mist outlet port of the equipment should be set at the top of the humidification site, within 50cm from the top, and the vertical distance from the mist outlet port to the equipment should be minimized as much as possible to maximize the efficiency of mist transmission. Therefore, atomization humidification equipment should be installed at a high position as much as possible.

  After selecting the installation location and height of the equipment, the mist outlet pipeline can be connected according to the specific situation in the humidification site. Firstly, if there is a high-speed airflow source in the humidification site, such as various high-speed fans, various gas injection ports, etc., the mist outlet pipeline port should be placed below the airflow source, with the outlet facing upwards, in order to use the high-speed airflow source for uniform gasification and diffusion; If the airflow is relatively static in a humidification area, it is necessary to consider extending the connection of the mist outlet pipeline in the humidification area, evenly distributing the mist outlet ports, and forming an angle of 30 degrees upward and horizontally for each mist outlet branch port to naturally float and vaporize the humidified water mist.

  2. Precautions during equipment installation

  The equipment should be installed horizontally. The PVC pipe fittings connected externally need to be sealed to prevent air and water leakage. When the external water supply pressure is insufficient, a pressurized water pump needs to be connected to ensure that the water supply pressure is greater than 1kg/cm3. The connection between the water inlet interface of the equipment and the water supply pipeline must be made using hoses with lock nuts on both sides. As there is a sealing ring inside the lock nut of this connecting hose, there is no need to wrap the connection thread to prevent water leakage. When connecting multiple devices on a water supply pipeline, each device's water supply branch must be connected to a water supply cutoff for easy maintenance and upkeep in the future. The newly installed water supply pipeline needs to first drain a certain amount of water for cleaning, in order to prevent impurities in the new pipeline from blocking the inlet solenoid valve and causing water supply failure.

  After the installation of the equipment is stable, the mist discharge pipeline of the equipment can be sealed and connected according to the pre designed pipeline direction. When connecting, attention should be paid to setting up a flange connection plate near the equipment point or connecting with a hose, which is convenient for future equipment maintenance and upkeep; In pipeline connection, the distance from the near end of the equipment is relatively low, and the distance from the far end of the equipment is relatively high. The lowest point of all fog outlets in the pipeline should be higher than 1/3 of the pipeline diameter to ensure that all accumulated water in the transmission pipeline flows back into the equipment, making the pipeline smooth; To ensure uniform distribution of humidification in the humidification space, the pipeline can be connected to several mist outlets according to the actual situation, and the diameter of the mist outlet can be selected according to the actual situation. The "U" shaped direction is prohibited in pipeline connections, as this type of connection can cause condensation and water blockage in the pipeline, affecting the normal operation of the equipment.


Read recommendations:

F11 Cooling Fan

A4 Aroma Diffuser

How to better choose an air purifier.air humidifier Factory

essential oil diffuser manufacturer

mini air purifier wholesale

Latest news

Hot

Inquiries

Contact the following for inquiries regarding our services and products.

Inquiry form